This is Harry back again. The water level is at around 18-19' even though the well point is deeper than that. The water pressure down there fills the pipe to the 18-19 foot level.
I am a little confused about the response saying the check valve is in the wrong location. I don't understand why it would make a difference where the check valve is located. It's function is the same wherever it is in the system. Isn't it?

Thanks again,
Harry

>Shallow well? Au
>contraire, mon frer
. You are attempting to do the
>impossible. Due to the limitations of atmospheric
>pressure, you cannot suck water up from that depth.
>Try pulling up the point a few feet. If that doesn't
>work, you will have to go with a deep well setup,
>which may be rather difficult with a 1.25 inch
>diameter well.

>
>>I sunk a shallow well here in Orlando Florida and am
>>having problems getting water out of it. Let me
>>describe my situation. I used a 5', 1 1/4" dia
>>stainless steel well point designed to be driven into
>>the ground. I used PVC pipe on top of the well point
>>(washed down, not driven)My water level is at 19'
>>below the surface. The top of the well point is at 27'
>>below the surface (8' below water level). Right on top
>>of the well point is a brass check valve. I can fill
>>the vertical pipe with water due to the check valve in
>>the bottom and obviously fill the pump before running.
>>I have tried a Harbor Freight shallow well pump:
>> >>href="http://www.harborfreight.com/cpi/ctaf/displayite
>m
>>.taf?Itemnumber=47906">http://www.harborfreight.com/cp
>i
>>/ctaf/displayitem.taf?Itemnumber=47906

>>and a 1Hp sprinkler pump from Lowes. I have not been
>>able to get water out of either of them. I know I am
>>priming well, I have water in the entire system from
>>the well point to the pump.
>>Any help would be greatly appreciated.
>>
>>Thanks,
>>Harry

[ Next Thread | Previous Thread | Next Message | Previous Message ]


VoyUser Login ] Not required to post.
Post a public reply to this message | Go post a new public message
* Notice: Posting problems? [ Click here ]
* HTML allowed in marked fields.
* Message subject (required):

* Name (required):

  Expression (Optional mood/title along with your name) Examples: (happy, sad, The Joyful, etc.) help)

  E-mail address (required):

* Type your message here:


Notice: Copies of your message may remain on this and other systems on internet. Please be respectful.

[ Contact Forum Admin ]


Forum timezone: GMT-8
VF Version: 2.94, ConfDB:
Before posting please read our privacy policy.
VoyForums(tm) is a Free Service from Voyager Info-Systems.
Copyright © 1998-2008 Voyager Info-Systems. All Rights Reserved.