Author:
mac@hi-pointe weld eqpt repair
|
[
Next Thread |
Previous Thread |
Next Message |
Previous Message
]
Date Posted: 03:44:27 01/20/04 Tue
In reply to:
Murdoc79RC
's message, "CC to CV" on 23:53:29 01/16/04 Fri
no, cc transformers are made differently than cv transformers, it would be expensive to replace the whole main transformer assembly and time to modify mounting the transformer, it would be more cost effective to get a cv welder or a voltage sensing wire feeder(it runs off the welder output terminals), if u opt for this type of feeder it can be a bit difficult to run .023 or .030 hard wire, voltage sensing feeders work better with flux core wire,good luck
[