VoyForums Announcement: Programming and providing support for this service has been a labor of love since 1997. We are one of the few services online who values our users' privacy, and have never sold your information. We have even fought hard to defend your privacy in legal cases; however, we've done it with almost no financial support -- paying out of pocket to continue providing the service. Due to the issues imposed on us by advertisers, we also stopped hosting most ads on the forums many years ago. We hope you appreciate our efforts.

Show your support by donating any amount. (Note: We are still technically a for-profit company, so your contribution is not tax-deductible.) PayPal Acct: Feedback:

Donate to VoyForums (PayPal):

04 /23/ 24, 9:44amLogin ] [ Contact Forum Admin ] [ Main index ] [ Post a new message ] [ Search | Check update time | Archives: 123[4]5678910 ]
Subject: Generator fuel consumption


Author:
Ken
[ Next Thread | Previous Thread | Next Message | Previous Message ]
Date Posted: 02/ 19/ 07, 5:42pm

Hi does anyone know what the fuel consumption on a kohler deisel generator, 84pt 35, I just purchased the coach and was amazed at how much fuel the generator used, right around 30 gallons in 12 hours does this sound right? It seems to start and run well, doesnt appear to be running rich, was thinking of pulling the injectors having them redone but If this is about normal then maybe not. That just seems like a ton of fuel for that motor.

[ Next Thread | Previous Thread | Next Message | Previous Message ]

Replies:
[> Subject: Re: Generator fuel consumption


Author:
Bill Schreurs
[ Edit | View ]

Date Posted: 02/ 19/ 07, 8:02pm

That does seem high. I have not checked it myself, but in my manual, I think it states 1/2 gallon per hour, but someone wrote in it beside that it is actually 3/4 gallon per hour.

[ Post a Reply to This Message ]
[> [> Subject: Re: Generator fuel consumption


Author:
ken
[ Edit | View ]

Date Posted: 02/ 20/ 07, 3:43am

Hi Peter, and thanks again, mine is a perkins, sorry about that,is that what yours is>?I looked through my manuel and it says nothing anywhere about rated fuel consumption, 1/2 gallon an hour or so would be great, I guess I could always disconnect the fuel line and draw it off a measured container of fuel.

[ Post a Reply to This Message ]


[> Subject: Re: Generator fuel consumption


Author:
George Frazer
[ Edit | View ]

Date Posted: 02/ 23/ 07, 9:33am

Hi
I will look in my book when I can find it, I have a PT40 with a 12.5 KW Kohler with a 4 cyl. Perkins. I just read a short time back, mine is supposed to burn a little over 1 gal. hr., less than 2 gal. I can't remember exact amount, a friend and I were discussing it and mine was real close to his gas 6.5 Onan, a little more but almost double KW. Check exhaust, should be at most a little haze under load, if it's overfueling, you should notice grey or black exh. The darker the color, the more unburned fuel, white smoke is unfired fuel. Check air filter first. I'm getting close to putting injectors in mine and think I can get dealer discounts, if you need a set, I'll check prices. Use my regular e-mail as I rarely get to this site.
Geo.
PT40

[ Post a Reply to This Message ]
[> [> Subject: Re: Generator fuel consumption


Author:
Ken
[ Edit | View ]

Date Posted: 02/ 24/ 07, 1:11am

Hi George, well I pulled the injectors and took them to a reptuble deisel injection service shop, I am going to change oil and filter, fuel filter, air filter, and adjust valves, then I will run it for exactly 2 hours and get an exact consumption reading at that point, then I will post it here.
Thanks again

[ Post a Reply to This Message ]
[> [> [> Subject: Re: Generator fuel consumption


Author:
Hi again Ken
[ Edit | View ]

Date Posted: 03/ 1/ 07, 10:15am

I just found info in my Kohler book and it says gen. should use 1.16 gph. under rated load. If you want, I can try to scan any info out of book and e-mail to you. If you need any other info, send me your e-maqil aqnd info you would like and I'll see what I can do.
Geo.

[ Post a Reply to This Message ]
[> [> [> [> Subject: Re: Generator fuel consumption


Author:
Ken
[ Edit | View ]

Date Posted: 03/ 21/ 07, 10:46am

Hi guys, well after replacing the injectors, air filter, and complete service then running for 1 hour with roof a/c's on, I brimmed the fuel tank right to the top, and It appears to have used just over a gallon of fuel, but drawing out of a 300 gallon tank its hard to tell for sure, once I start using it more regularly I will have a better idea, but obviuosly the injectors definetly helped, thanks for your help on this one

[ Post a Reply to This Message ]



Post a message:
This forum requires an account to post.
[ Create Account ]
[ Login ]
[ Contact Forum Admin ]



Forum timezone: GMT-8
VF Version: 3.00b, ConfDB:
Before posting please read our privacy policy.
VoyForums(tm) is a Free Service from Voyager Info-Systems.
Copyright © 1998-2019 Voyager Info-Systems. All Rights Reserved.