Subject: Re: 50 Amp service |
Author: Bill Schreurs
| [ Next Thread |
Previous Thread |
Next Message |
Previous Message
]
Date Posted: 02/ 19/ 07, 8:31pm
In reply to:
ken
's message, "Re: 50 Amp service" on 02/ 19/ 07, 5:32pm
Ken:
Wow, I do not read this forum often, maybe I will from now on.
I have to dispute a number of things which Peter has said, and also what you have done.
Gosh, you are setting yourself up, or someone else, to get killed.
The 50 amp plug has only three prongs, and the fourth is the steel case at the ends. The cable with the red painted ends is exactly that - 50 amp 240 volt service.
You mention that when you run the generator the one leg does not show any power either, are you looking at voltage or current.
If that is the case, maybe the cords are ok, it could be the selector switch, 30/50/gen etc. Try moving the selector switch.
Now about killing someone - NEVER, NEVER in a RV should the ground and neutral be connected together. If you were to connect them together, and if you lost the ground connection, and someone came and touched the coach under the right conditions, they could possibly be the ground path, causing either serious or fatal injuries.
Ken, email me if you wish, then maybe we can talk on telephone, and then you can print here what you found.
[