VoyForums Announcement: Programming and providing support for this service has been a labor of love since 1997. We are one of the few services online who values our users' privacy, and have never sold your information. We have even fought hard to defend your privacy in legal cases; however, we've done it with almost no financial support -- paying out of pocket to continue providing the service. Due to the issues imposed on us by advertisers, we also stopped hosting most ads on the forums many years ago. We hope you appreciate our efforts.

Show your support by donating any amount. (Note: We are still technically a for-profit company, so your contribution is not tax-deductible.) PayPal Acct: Feedback:

Donate to VoyForums (PayPal):

Login ] [ Contact Forum Admin ] [ Main index ] [ Post a new message ] [ Search | Check update time | Archives: 1234[5] ]
Subject: Re: 1991 Accord EXR : Cooling Fan stays ON!


Author:
Spredvan
[ Next Thread | Previous Thread | Next Message | Previous Message ]
Date Posted: 13:49:53 12/03/03 Wed
Author Host/IP: NoHost/170.160.9.3
In reply to: Dan Grigorescu 's message, "1991 Accord EXR : Cooling Fan stays ON!" on 20:37:21 12/02/03 Tue

Based on the info you have provided, I would suspect a faulty Cooling Fan Relay. Let's start ther first. The fan has to be running for this test...

The cooling fan is turned on by the "Cooling Fan Relay". When the relay coil is energized, the relay contacts close and 12 volts is applied to the fan.
This relay could be bad, and the contacts could be "welded" closed.

When the fan is running, disconnect the connector from the "Cooling Fan Temperature Switch". This is the switch in the thermostat housing (which is behind the distributor, where the lower radiator hose terminates). When you remove the connector, the relay should drop out and open its contact to deenergize the fan. If the fan keeps running, the relay is bad.

The relay is located in the passenger-side engine compartment relay box. It is the outboard, aft mounted relay. If it's operating OK, you can put your fingers on the relay and feel it operate as you put the connector on and off.

Post again with the results, and if the relay operates OK, we'll move to the Temperature Switch.

Good luck...

Mike

[ Next Thread | Previous Thread | Next Message | Previous Message ]

Replies:
Subject Author Date
Re: 1991 Accord EXR : Cooling Fan stays ON!Dan Grigorescu09:30:02 12/04/03 Thu


Post a message:
This forum requires an account to post.
[ Create Account ]
[ Login ]
[ Contact Forum Admin ]


Forum timezone: GMT-6
VF Version: 3.00b, ConfDB:
Before posting please read our privacy policy.
VoyForums(tm) is a Free Service from Voyager Info-Systems.
Copyright © 1998-2019 Voyager Info-Systems. All Rights Reserved.